Triple Pump Hydrophore

Specifications

- Our products comply with TS EN 733 standards.
- Temperature range of the liquid: 20 - 600C
- Temperature range of the liquid: 20 - 600C
- Operating Ambient temperature up to 400C
- Max. suction head up to 8 m
- Max. head up to 170 m
- Body Pressure (Pmax) 10-16-25 bar
- Sequential operation according to water need.
- Pump replacement after each operation.
- Pumps stop when there is no water in the suction.
- Delay during start-up of the 2nd and 3rd pumps.
- Delay during deactivation of the 2nd and 3rd pumps.
- Ability to read the interphase voltage from the screen on the microprocessor unit.
- The fault can be read via the microprocessor.
- All operating statuses can be seen on the control panel.
- Additionally, there is an additional manual operation switch on the side surface of the panel. (For models above 5.5 kW)

Engine Specifications

- Standard type B'5 flange, 2-pole, three-phase, 50 Hz [2900 rpm] electric motor.
- Insulation Class: F | Protection Class: IP 55


Materials Provided with the Booster

- Suction and discharge collector.
- Full bore ball valves.
- Silent operating missile type check valve.
- Level floater with 5 Mt cable that prevents operation without water.
- Control panels with high-equipped sequence changer feature, P.01 up to 5.5 kW, Y/D starting for 7.5 KW and above, mounted on the chassis.
- Anti-vibration elastic wedges


Code : ASN-F 80-06

Product Catalog

Capacity and Sizes


Assembly Diagram



Get price offer and info for your water storage and transfer projects.

You can schedule an online meeting with our experts and get information about water storage and transfer technologies and get projects and price quotes.